Orifice Type Gravity Pan Distributor Tower Internals

  • 1
  • 2

Certification : ISO 9001

Place of Origin : China

MOQ : 1 unit

Price : Negotiation

Payment Terms : L/C, T/T

Supply Ability : 99 units per month

Delivery Time : 5-9 days

Packaging Details : pallet, wooden box

Position : On top of tower packing

type : gravity type

Advantage : good performance

Material : stainless steel, or as per order

Application : liquid distributing

Design service : yes

Contact Now

Small diameter tower internal orifice type gravity pan distributor

1. Pan distributor is belong to column internals

Column internals play very important role in effective mass transfer performance. So they need to be designed carefully for both process and mechanical point. Meanwhile, the engineers put great effort into structured packing and random packing development in the recent years. The column internals include mist eliminators, feed pipes, distributors, re-distributors, support plates, bed limiters, collector trays, etc.

2. Pan distributor is a kind of orifice gravity liquid distributor

Orifice type gravity distributor usually shows as pan type. An orifice pan distributor consists of a pan. There are circular or rectangular risers for vapor flow and perforation for liquid flow in the pan.Orifice type distributor can be designed to have a large number of drip points to provide superior liquid distribution, though it may suffer from corrosion and plugging. Orifices are sized to maintain a minimum liquid head at desired turndown conditions & to avoid distributor overflow during turn up condition. Very small orifice diameters (<4mm) are avoided to prevent fouling.

3. Pan distributor application circumstances

Column Diameter

inches

Specific liquid load

gpm/ft2

System fouling tendency Turndown ratio Suitable type of liquid distributor
10-36 0.3 - 2 Low - medium <10:1

Trough type liquid distributor with sump

Deck type liquid distributor with orifices on drip tubes

2 - 12 Low - medium 2:1

Pan type liquid distributor

Trough type liquid distributor with sump

>12 Low - medium 2:1

Pan type liquid distributor

Trough type liquid distributor with sump

Deck type liquid distributor

>36 0.3 - 2 Low - medium <10:1

Trough type liquid distributor with parting box

Deck type liquid distributor with orifices on drip tubes

2 - 12 Low - medium 2:1

Trough type liquid distributor with sump

Trough type liquid distributor with parting box

Deck type liquid distributor

>12 Low - medium 2:1

Deck type liquid distributor

Trough type liquid distributor with sump

4. Important points in designing Pan liquid distributor:

There are some important points to be checked before finalizing the liquid distributor design.

  • Maximum and Minimum head:

Maximum liquid head is the actual liquid head on the distributor deck at turn up condition. The overall height of the liquid distributor (trough / riser) shall be higher than this maximum head. Please refer to the following formula.

Riser (Trough) height = {(Maximum head) 1.10 + 25} mm

Minimum head on the distributor is always to be estimated as per requirement at turn down condition. Liquid vortexing and entrainment may happen at low liquid head as insufficient resistance to orifices. Also considerable mis-distribution can occur if minimum heads are fallen short of. So the minimum liquid head on the distributor shall be around 35mm. Punched orifices, instead of drilled orifices, are always recommended in the direction of liquid flow.

  • Pressure drop and open area requirement for vapor:

Sufficient gas passage area must be provided by the liquid distributor according to gas load, to avoid liquid entrainment or high pressure drop. A minimum of 12% open area is used when very low open area is required for gas. The pressure drop of liquid distributor shall not exceed a value of 20mm water column. Well, it finally depends on gas load, liquid load and a particular service.

  • Flow variation:

Flow variation will increase due to low liquid head at the time of low liquid loads and / small column diameters. Flow variation is a strong function of mechanical points such as plate levelness, distributor deck flatness etc. Liquid mis-distribution and entrainment may occur on below packed bed with excessive flow variation. So we need to minimise the excessive flow variation. The liquid distributor or re-distributor can allow maximum of 12% flow variation.

5. Pan distributor production laser cutting machine

Orifice Type Gravity Pan Distributor Tower Internals

Welcome your contact with your private tower internals plan or ideas!


Product Tags:

pan distributor tower internals

      

gravity tower internals

      

orifice type tower internals

      
China Orifice Type Gravity Pan Distributor Tower Internals wholesale

Orifice Type Gravity Pan Distributor Tower Internals Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Silk Road Enterprise Management Services Co.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)